top of page

Pressure Decay Leak Testing: How It Works and How to Set Limits

Writer: Tech Inc
Tech Inc
5 hours ago
1 min read

At a glance. The part is filled with air to a test pressure, isolated, allowed to stabilise and then watched for a fall in pressure. The leak rate is Q = V·ΔP ÷ (t·Patm), where V is the internal volume. The Tech Inc. Automated Pressure Decay Leak Tester runs the cycle in seconds and logs every result.

The test cycle

Phase

Purpose

Fill

bring the part to test pressure

Stabilise

let temperature and stretch settle

Test

measure pressure decay

Vent

release pressure safely

Setting limits

  1. Define the leak rate the product can accept.

  2. Measure the part volume, including fixture volume.

  3. Choose test time long enough to resolve that leak.

  4. Validate with a calibrated leak standard.

When to use other methods

  • Differential pressure for smaller leaks, comparing against a sealed reference.

  • Mass flow for larger leaks or big volumes.

  • Helium for very small leaks.

Frequently asked questions

Why do results drift? Usually temperature: warm parts from upstream processes cool during the test. Longer stabilisation helps.

Can it test filters? For filter integrity, use our integrity tester.