Capillary Pressure by Porous Plate: The Reference Method

At a glance. Brine-saturated cores sit on a water-wet ceramic plate in a pressure cell. Gas or oil pressure is raised in steps; at each step brine leaves the cores through the plate until equilibrium, and the volume gives saturation. The Tech Inc. Capillary Pressure Porous Plate System tests many cores at once.
Method comparison
Method | Speed | Fluids | Notes |
Porous plate | weeks | gas–brine, oil–brine | true equilibrium; reference method |
Centrifuge | days | gas–brine, oil–brine | needs data correction |
Mercury injection | hours | mercury–vacuum | fast; converted to reservoir fluids |
Running a good test
Use a plate with entry pressure above the highest step.
Ensure good capillary contact (paper or diatomaceous layer).
Wait for equilibrium at each step: no more brine collected.
Weigh cores at the end to check saturations.
Uses
Irreducible water saturation.
Saturation-height functions.
Preparing cores at known saturation for resistivity index tests.
Frequently asked questions
How many cores per cell? Up to 12 in the large cell.
Why so slow? Flow through the low-permeability plate and the core takes time to reach equilibrium.