The Tech Inc. Pressure-Leach Autoclave and Alloy Leach Reactor leaches metals from spent catalysts, concentrates and residues under pressure, where atmospheric tanks are too slow or too weak. A stirred autoclave in titanium, C-276 or lined steel holds the slurry at temperature with oxygen or acid; jackets or coils control temperature, and the discharge is flashed and cooled before filtration. Laboratory and pilot sizes give the data for production plants.
At a glance: about 5 to 200 L · to about 250 °C and 50 bar · titanium, C-276 or lined · oxygen by mass flow · flash, cool and filter
Main components
- Stirred autoclave in titanium, C-276 or lined steel
- Magnetic or double mechanical seal agitator
- Oxygen or gas addition with mass-flow control
- Heating jacket or internal coils
- Flash and cooling vessel
- PLC with temperature, pressure and safety interlocks
Applications: catalyst and metal recyclers, research laboratories in mining and metallurgy, battery recyclers and pilot plants for new leach routes.
Send your process data and specification to mail@techincresearch.com or call +1 (289) 622-1032 for a P&ID, GA drawing and quotation.