top of page

The Tech Inc. Coupled-Valve Closed Sampler takes a fixed volume of liquid from a pipe or loop and delivers it into a closed sample bottle, with no spill and no vapour reaching the operator. One handle drives two mechanically coupled valves: the first position fills the calibrated chamber from the flowing process, the second isolates it from the process and drains it through a closed needle into the bottle, so the process can never flow straight into the bottle.

At a glance: about 10 to 100 mL fixed volume · one handle, coupled valves · to about 50 barg · threaded, welded or flanged · 316L to C-276 or PTFE-lined

Download the datasheet (PDF)

 

Main components

  • Machined sampler body with internally coupled inlet and outlet valves
  • Calibrated fixed-volume chamber, interchangeable for different volumes
  • Single operating handle with lockable positions
  • Bottle holder with closed needle connection and vent needle
  • Vent line to flare, closed drain or carbon canister
  • Enclosure, heat tracing and purge connections as options

 

Applications: refineries, petrochemical and fertiliser plants, LNG and gas-processing plants, chemical plants handling toxic or flammable liquids, and any unit where operators must not be exposed during sampling.

 

Send your process data and specification to mail@techincresearch.com or call +1 (289) 622-1032 for a P&ID, GA drawing and quotation.

Coupled-Valve Closed Sampler