top of page
< Back

TICONT Contact Angle Analyser Series – 9 Models

Tech Inc. makes contact angle analysers as a series, not a single instrument. The TICONT range runs to nine models, from the 0.5 kg TI 125 that sits on the part being measured to the fully automatic TI 1005K, all with the same drop-shape software and 465 nm light source. Choose by sample size, by how much of the measurement should be automated, and by the camera speed the surface needs.

Which TICONT model

  • Routine checks on membrane coupons and films: TI 165 or TI 205 (manual, 130 × 150 mm platform, 80 frames/s).

  • Repeatable drop volumes with software dispensing: TI 205K (benchtop) or TI 405K (400 frames/s, 0.001 µl).

  • Porous or fast-absorbing surfaces, dynamic angles: TI 405 or TI 405K (400 frames/s, collimated light, automatic liquid addition).

  • Large sheets, panels and coated parts: TI 605 (300 × 300 mm sliding-rail platform) or TI 605K (adds automatic tilting and pipetting).

  • Unattended measurement series: TI 1005K (automatic tilting, pipetting and liquid addition).

  • Installed parts, pipes and field work: TI 125 portable.

The nine models

TICONT TI 165 – Entry-level benchtop analyser

Manual stage, tilting and dispensing with a 130 × 150 mm platform, 80 frames/s USB 2.0 camera and 0.1 µl drip accuracy. The starting point for routine wettability checks on membrane coupons and films.

  • Instrument dimensions: 505 × 168 × 460 mm

  • Instrument weight: 8.6 kg

  • Platform size: 130 × 150 mm

  • Moving range: X 30, Y 50, Z 30 mm

  • Platform tilting: Manual

  • Drip sampling method: Manual rotary knob

  • Pipetting method: Manual

  • Drip accuracy: 0.1 µl

  • Maximum shooting speed: 80 frames/s

  • Camera connection: USB 2.0

  • Light source type: Standard

  • Power consumption: 5 W

TICONT TI 205 – Manual benchtop analyser

The same manual platform as the TI 165 with a 1000 µl micro sample injector, for laboratories that run many measurements a day on flat samples.

  • Instrument dimensions: 505 × 168 × 460 mm

  • Instrument weight: 8.6 kg

  • Platform size: 130 × 150 mm

  • Moving range: X 30, Y 50, Z 30 mm

  • Platform tilting: Manual

  • Drip sampling method: Manual rotary knob

  • Pipetting method: Manual

  • Drip accuracy: 0.1 µl

  • Maximum shooting speed: 80 frames/s

  • Camera connection: USB 2.0

  • Light source type: Standard

  • Power consumption: 5 W

TICONT TI 205K – Semi-automatic benchtop analyser

Adds software-controlled dispensing and a 50 mm drip-control movement to the benchtop platform; stage movement is manual or automatic.

  • Instrument dimensions: 505 × 168 × 450 mm

  • Instrument weight: 9 kg

  • Platform size: 130 × 150 mm

  • Moving range: X 30, Y 50, Z 30 mm

  • Platform tilting: Manual

  • Drip sampling method: Software automation

  • Pipetting method: Manual / automatic

  • Drip accuracy: 0.1 µl

  • Maximum shooting speed: 80 frames/s

  • Camera connection: USB 2.0

  • Light source type: Standard

  • Power consumption: 15 W

TICONT TI 405 – High-speed research analyser

Software-controlled dispensing with 0.001 µl drip accuracy, automatic liquid addition, a 400 frames/s USB 3.0 camera and collimated light source for dynamic and advancing/receding angles.

  • Instrument dimensions: 630 × 180 × 500 mm

  • Instrument weight: 10 kg

  • Platform size: 130 × 150 mm

  • Moving range: X 30, Y 50, Z 30 mm

  • Platform tilting: Manual

  • Drip sampling method: Software automation

  • Pipetting method: Manual

  • Drip accuracy: 0.001 µl

  • Maximum shooting speed: 400 frames/s

  • Camera connection: USB 3.0

  • Light source type: Collimated

  • Power consumption: 15 W

TICONT TI 405K – High-speed analyser with automatic pipetting

The TI 405 platform with automatic pipetting and automatic liquid addition, for repeatable drop volumes without operator influence.

  • Instrument dimensions: 630 × 180 × 500 mm

  • Instrument weight: 10.8 kg

  • Platform size: 130 × 150 mm

  • Moving range: X 30, Y 50, Z 30 mm

  • Platform tilting: Manual

  • Drip sampling method: Software automation

  • Pipetting method: Automatic

  • Drip accuracy: 0.001 µl

  • Maximum shooting speed: 400 frames/s

  • Camera connection: USB 3.0

  • Light source type: Collimated

  • Power consumption: 33 W

TICONT TI 605 – Large-platform analyser

300 × 300 mm sliding-rail platform with X 130, Y 170, Z 50 mm travel, for large sheets, panels and coated parts; 400 frames/s camera, manual dispensing.

  • Instrument dimensions: 950 × 380 × 550 mm

  • Instrument weight: 30 kg

  • Platform size: 300 × 300 mm

  • Moving range: X 130, Y 170, Z 50 mm

  • Platform tilting: Manual

  • Drip sampling method: Differential knob

  • Pipetting method: Manual

  • Drip accuracy: 0.1 µl

  • Maximum shooting speed: 400 frames/s

  • Camera connection: USB 3.0

  • Light source type: Collimated

  • Power consumption: 5 W

TICONT TI 605K – Large-platform analyser with automatic tilting

The 300 × 300 mm platform with automatic tilting, automatic pipetting and software-controlled dispensing, for roll-off and sliding-angle studies on large samples.

  • Instrument dimensions: 950 × 380 × 550 mm

  • Instrument weight: 30 kg

  • Platform size: 300 × 300 mm

  • Moving range: X 130, Y 170, Z 50 mm

  • Platform tilting: Automatic

  • Drip sampling method: Software automation

  • Pipetting method: Automatic

  • Drip accuracy: 0.1 µl

  • Maximum shooting speed: 400 frames/s

  • Camera connection: USB 3.0

  • Light source type: Collimated

  • Power consumption: 33 W

TICONT TI 1005K – Fully automatic analyser

Automatic platform tilting, automatic pipetting, automatic liquid addition and 0.001 µl drip accuracy with a 400 frames/s camera, for unattended measurement series.

  • Instrument dimensions: 630 × 180 × 530 mm

  • Instrument weight: 20 kg

  • Platform size: 130 × 150 mm

  • Moving range: X 30, Y 50, Z 30 mm

  • Platform tilting: Automatic

  • Drip sampling method: Software automation

  • Pipetting method: Automatic

  • Drip accuracy: 0.001 µl

  • Maximum shooting speed: 400 frames/s

  • Camera connection: USB 3.0

  • Light source type: Collimated

  • Power consumption: 51 W

TICONT TI 125 – Portable analyser

0.5 kg, 80 × 44 × 140 mm, placed directly on the surface being measured, so platform size is unlimited: field checks on panels, pipes, coatings and installed parts.

  • Instrument dimensions: 80 × 44 × 140 mm

  • Instrument weight: 0.5 kg

  • Platform size: Unlimited (sits on the sample)

  • Moving range: Unlimited

  • Platform tilting: Manual

  • Drip sampling method: Manual rotary knob

  • Pipetting method: Manual

  • Drip accuracy: 0.1 µl

  • Maximum shooting speed: 80 frames/s

  • Camera connection: USB 2.0

  • Light source type: Standard

  • Power consumption: 2 W

Common to all nine models

  • Input power: 220 V, 50–60 Hz

  • Lens: 0.7× to 4.5×

  • Focal length: ±2.5 mm adjustable

  • Image capture: Single shot, by interval, continuous

  • Shooting interval: 500 ms to 3,600,000 ms

  • Video: Recording, playback and synthesis

  • Light source wavelength: 465 nm

Frequently asked questions

What does a contact angle analyser measure?

The angle a liquid drop makes with a surface, which shows how hydrophilic or hydrophobic it is. Advancing and receding angles and surface free energy can also be calculated.

Sessile drop or captive bubble for membranes?

Captive bubble measures the membrane wet, as it is used; sessile drop is quicker for dry films. On porous membranes, record the angle at a fixed time because the drop soaks in, which is why the 400 frames/s models suit MF and UF membranes.

Why does the series have K models?

K models add automation: software-controlled dispensing and pipetting on the 205K and 405K, automatic tilting on the 605K, and automatic tilting, pipetting and liquid addition on the 1005K.

Can you test my samples first?

Yes. We run contact angle measurement as a contract service, so you can see the method on your own materials before choosing a model.

What to send for a quotation

Sample types and sizes, the methods you need (sessile drop, captive bubble, pendant drop, tilting), the test liquids, how many measurements a day and whether you need surface free energy calculation. Write to mail@techincresearch.com or call +1 (289) 622-1032.

Related: surface free energy (OWRK) calculator, contact angle measurement on membranes, contact angle measurement equipment range.

Specifications are typical and may change without notice; performance depends on the sample, the method and operation in line with the operation manual. Confirm the current datasheet before ordering.

90ed08_454478c761254755af637af46eb7b54a~mv2.png

Nine TICONT contact angle analysers from the portable TI 125 to the fully automatic TI 1005K: platform size, automation and camera speed compared.

ANFRAGE ABSENDEN

Danke fürs Einsenden! Wir werden uns so schnell wie möglich mit Ihnen in Verbindung setzen

Trusted by industry and research leaders

Saudi Aramco Approved Vendor · ISO 9001 · ISO 14001 · GMP

References: Saudi Aramco · Los Alamos National Laboratory · NTPC · Thermax · Purity ReSource · Clarkson University · UTPB

bottom of page