top of page

From Coupon to Element: Using Spiral-Wound Test Housings for Scale-Up

10 hours ago
1 min read

At a glance. Elements behave differently from coupons: longer channels, glue lines and permeate tubes all matter. Tech Inc. Spiral-Wound Element Test Housings take 1812 to 4040 elements in SS316 or FRP.

A simple scale-up path

  1. Screen membranes in flat cells.

  2. Roll a small 1812 or 2540 element.

  3. Test it in a housing on a pilot skid.

  4. Confirm with 4040 elements before design.

What to specify

  • Element size and number in series.

  • Pressure rating: RO or NF.

  • Side or end ports to suit the skid.

Frequently asked questions

Can we test incoming elements? Yes; many plants use 4040 housings for QC of supplied elements.

Contact mail@techincresearch.com for housings and pilot skids.