The LACT Unit: Unattended Crude Custody Transfer Every Producer Should Have
At a glance. When crude changes hands at a lease or production facility, the producer and purchaser both need an accurate, auditable measurement. The Tech Inc. LACT Unit pumps the oil, removes air and debris, checks water content, diverts off-spec oil, meters the good oil and takes a representative sample, without an operator. For crude producers, it is one of the best investments they can make.
What happens inside a LACT unit
A charge pump feeds the unit at a steady pressure.
A strainer-air eliminator removes debris and air.
A BS&W monitor checks water content; off-spec oil is diverted automatically.
The custody meter measures the good oil.
An automatic sampler fills a receiver in proportion to flow.
A flow computer records every transfer; prover connections allow field proving.
Configurations
Version | Use |
Standard LACT | Single run, one skid |
Twin-run LACT | Higher flow or redundancy |
LACT with prover | Compact or ball prover on the same skid |
Why it is one of the best things to happen to crude producers
Unattended transfer. Measures, samples and diverts on its own.
Accurate quantity. Air and debris removed before the meter.
Off-spec protection. Water cut checked and bad oil diverted automatically.
One skid. Pump, conditioning, meter, sampler and controls built and tested together, designed to API MPMS Chapter 6.1.
Tech Inc. builds the strainer-air eliminator, sampler and receiver on the skid itself.
Frequently asked questions
What meter does a LACT unit use?
Positive displacement, turbine or Coriolis, from a leading maker, to the client's specification.
Does the unit need an operator?
No. It measures, samples and diverts off-spec oil automatically.
Can the meter be proved in the field?
Yes. Prover connections are standard, and a prover can be mounted on the same skid.
Send your flow rate, crude properties and transfer point details to mail@techincresearch.com or call +1 (289) 622-1032 for a P&ID and quotation.