top of page

Steam Sampling Systems are purpose-engineered systems for collecting representative steam samples from boilers, turbines, and steam distribution networks in power generation and industrial process facilities. These specialized systems are critical for monitoring steam purity, detecting contaminants, and ensuring compliance with industry water chemistry standards and regulatory requirements.

Download the datasheet (PDF)

 

System Design & Capabilities:

Our steam sampling systems incorporate dual-stage cooling technology to safely reduce sample temperature while maintaining sample integrity. The systems employ isokinetic sampling nozzles that extract representative steam samples proportional to flow conditions, eliminating sampling bias and ensuring accurate chemical analysis results.

 

  • Primary and secondary cooling stages for safe, representative sample handling
  • Isokinetic sampling nozzles designed per ASTM D1066 standards for accurate sample extraction
  • Integrated sample conditioning panels with precision temperature and pressure regulation
  • Capability for simultaneous silica, sodium, and conductivity monitoring
  • Engineered for continuous online sampling or grab sampling operation as required
  • ASME, PED, and CE compliance certifications for global industrial standards

 

Applications:

  • Thermal and nuclear power plant boiler feed water monitoring
  • Co-generation facility steam quality assurance
  • Boiler water treatment program optimization and control
  • Steam-driven industrial process plants requiring purity verification
  • District heating system water chemistry management
  • Pharmaceutical steam sterilization quality verification

 

Why Choose Tech Inc?

As a Saudi Aramco-approved vendor, Tech Inc designs steam sampling systems in Canada and manufactures them in India with ISO-compliant quality assurance. We provide turnkey solutions including system design, fabrication, installation support, and commissioning assistance to ensure optimal performance in your facility.

 

SWAS panels

The Tech Inc. Steam and Water Analysis System (SWAS) is a complete system that collects, cools and conditions samples from boilers and heat-recovery steam generators (HRSGs) and measures water chemistry continuously. Plant chemists and operators use it to control the water-steam cycle and protect boilers and turbines from corrosion and deposits.

 

Main components

  • Double-coil sample coolers
  • Pressure-reducing valves
  • Back-pressure regulators
  • Chilled-water secondary cooling
  • High-temperature and high-pressure isolation valves
  • Grab-sample sink
  • Sample flow indication

 

Measurements integrated

  • Specific, cation and degassed conductivity
  • pH
  • Dissolved oxygen
  • Silica
  • Sodium
  • Phosphate
  • Hydrazine or oxygen scavenger

 

Applications: HRSGs, utility and industrial boilers, power plants, refinery and petrochemical steam systems, and desalination plants.

 