The Tech Inc. Closed-Circuit RO (CCRO) Pilot Test Skid proves how far a feed water can be recovered before scaling or fouling sets in. It runs the closed-circuit, semi-batch cycle: feed enters the loop at the rate permeate leaves, a circulation pump keeps crossflow through short vessels, pressure rises with concentration, and at the set recovery a flush valve displaces the brine with fresh feed while production continues.
Main components
- Feed tank, cartridge prefilter and antiscalant dosing point
- High-pressure feed pump on VFD
- Circulation pump on VFD for loop crossflow
- One to three pressure vessels for 4- or 8-inch elements, one to four elements each
- Automatic flush (brine purge) valve and conductivity-based cycle control
- Pressure, flow, conductivity, pH and temperature transmitters
- PLC and HMI with cycle logic, data logging and remote access
Applications: Brackish and well water, RO reject recovery, cooling-tower blowdown, mine and industrial wastewater reuse, and ZLD pre-concentration studies.
Send your feed-water analysis, target recovery and test plan to mail@techincresearch.com or call +1 (289) 622-1032 for a P&ID, GA drawing and quotation.


