The Tech Inc. Nitrogen Purge and Calibration Gas Panel (model TI-PGPHP) supplies regulated nitrogen and calibration gases to the syngas analyser systems of gasification plants. Nitrogen purges sample lines and analyser housings, makes the sample path inert before maintenance and drives probe blowback. Calibration gases are switched to the analysers on demand or on a set schedule, keeping readings accurate between services.
Main components
- Nitrogen inlet with filter, pressure regulators and gauges
- Purge and blowback distribution with solenoid valves and flow indicators
- Calibration gas cylinder connections with regulators
- Calibration gas selection valves, manual or automatic
- Relief valves and vent connections to a safe location
- Pressure switches and alarms for low nitrogen supply
- Stainless steel tubing on an open panel, rack or enclosure
Applications: syngas analyser systems, heated probe blowback, sample line purging, analyser housing purge and analyser calibration on coal gasification plants feeding methanol, ammonia, hydrogen and synthetic natural gas units.
Send your process data and specification to mail@techincresearch.com or call +1 (289) 622-1032 for a P&ID, GA drawing and quotation.